Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
1.
Cureus ; 16(1): e52343, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38361701

RESUMO

Oral and maxillofacial surgeons are often faced with the clinical challenge of foreign body displacement into the perioral tissues and soft tissues of the head and neck. This mainly occurs either because of trauma or inadvertently during dental treatment. In addition to the maxillary sinus, iatrogenic foreign body displacement during dental treatment could happen into one of the 16 distinct fascial spaces of the head and neck region. Commonly displaced foreign bodies related to dental treatment include tooth roots or fragments, local anesthetic needles, implants and restorations. The clinical sequelae of a displaced foreign body depend on its size, shape, anatomic location and proximity to vital structures. Although patients may remain asymptomatic for a considerable amount of time, retained foreign bodies result in persistent pain, recurrent infection and scarring of soft tissue due to inflammation, all of which may complicate delayed retrieval. In addition to the history, imaging modalities such as plain radiographs and computed tomography (CT) help in locating the displaced foreign body and its subsequent retrieval. Surgical retrieval may be attempted through intraoral, transcervical and endoscopic approaches. Additionally, surgery may be aided by real-time imaging such as fluoroscopy. The present report aims to detail a case of inadvertent displacement of an orthodontic mini-screw, commonly used as a temporary anchorage device (TAD), into the lateral pharyngeal space, while attempting placement in the mandibular retromolar area. The case report also describes the surgical retrieval procedure of the TAD screw using an intraoral approach and with fluoroscopy guidance using C-Arm radiographic imaging. This case is reported along with the pertinent review of literature, as it not only explains a rare complication of orthodontic mini-screw placement but also details a modality to remove displaced foreign bodies from fascial spaces of the head and neck, which are otherwise directly inaccessible.

2.
Angle Orthod ; 94(1): 107-121, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37870251

RESUMO

OBJECTIVES: To evaluate the effectiveness of distalizing maxillary first molars (U6) by temporary anchorage devices (TADs) according to their location (palatal, buccal, and zygomatic), their number, and appliance design. MATERIALS AND METHODS: An electronic search of maxillary molar distalization with TADs was done through April 2023. After study selection, data extraction, and risk-of-bias assessment, meta-analyses were performed for the extent of distalization, distal tipping, and vertical movement of U6 using the generic inverse variance and random-effects model. The significance level was set at 0.05. RESULTS: Forty studies met the inclusion criteria: 4 randomized controlled trials (RCTs), 13 prospective studies, and 23 retrospective studies (total of 1182 patients). Distalization of the U6 was not significantly greater (P = .64) by palatal (3.74 mm) and zygomatic (3.68 mm) than by buccal (3.23 mm) TADs. Distal tipping was significantly higher (P < .001) in nonrigid (9.84°) than in rigid (1.97°) appliances. Vertical movement was mostly intrusive and higher but not significantly different (P = .28) in zygomatic anchorage (-1.16 mm). CONCLUSIONS: Distalization of U6 with TADs can be an effective and stable treatment procedure, especially when performed with rigid palatal appliances. However, further RCTs or prospective cohort studies are strongly recommended to provide more clinical evidence.


Assuntos
Má Oclusão Classe II de Angle , Procedimentos de Ancoragem Ortodôntica , Humanos , Má Oclusão Classe II de Angle/terapia , Aparelhos Ortodônticos , Maxila , Técnicas de Movimentação Dentária , Desenho de Aparelho Ortodôntico , Dente Molar , Cefalometria/métodos
3.
Stomatologiia (Mosk) ; 102(6): 52-61, 2023.
Artigo em Russo | MEDLINE | ID: mdl-37997314

RESUMO

The case of treatment of a 32-year-old patient with complaints about the aesthetics of a smile and the absence of teeth 17 and 46 is presented. During the examination, it was established: the retraction position of the teeth in the frontal part of the upper jaw, the closure of the molars according to the II class of the second subclass of Engl (distal bite), the vestibular position of the teeth 13, 23. To change the spatial position of the lower jaw, the fixation of the bracket system on the upper jaw was performed. and also an individualized mini-plate was installed in the area of the zygomatic alveolar ridge on the right and left, for distalization of the dentition of the upper jaw with the help of orthodontic traction applied from the teeth to the mini-plates. This clinical example demonstrates the possibility of using individualized mini-plates for distalization of the upper dentition, as an alternative and more stable method of treatment in such clinical cases.


Assuntos
Má Oclusão Classe II de Angle , Dente Molar , Humanos , Adulto , Dente Pré-Molar/cirurgia , Maxila , Mandíbula , Processo Alveolar , Técnicas de Movimentação Dentária/métodos , Má Oclusão Classe II de Angle/terapia , Cefalometria/métodos , Desenho de Aparelho Ortodôntico
4.
J Lasers Med Sci ; 14: e42, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38028875

RESUMO

Introduction: This study aimed to evaluate the influence of two recycling methods on the mechanical and surface characteristics of orthodontic mini-screws. Methods: Thirty-six retrieved mini-screws were randomly classified into two equal groups. In the first group (laser recycled group (LG)), the Er:YAG laser (2940 nm, 5.5 W, 275 mJ, perpendicular to the mini-screws at a distance of 7-10 mm, 25 s) was used to recycle mini-screws. In the second group (phosphoric acid and sodium hypochlorite recycled group (ASG)), the mini-screws were kept in 37% phosphoric acid gel (10 minutes) and then placed in 5.25% sodium hypochlorite for 30 minutes. Eighteen new mini-screws were selected as the control group (CG). Maximum insertion torque (MIT), maximum removal torque (MRT), and fracture torque (FT) of all mini-screws were measured. A sample from each group was examined for the surface changes of the mini-screw and tissue remnants under a scanning electron microscope (SEM). Results: The mean MIT was significantly higher in both LG and ASG groups than the CG (P<0.001 and P=0.002, respectively). However, no significant difference was shown between the LG and ASG groups. The mean values of MRT and FT showed no significant difference between the groups. The amount of tissue remnants in the ASG group was significantly higher than that in the LG group. The evidence of porosity and corrosion was observed on the ASG mini-screw surface, and there was an increase in roughness on the LG mini-screw surface. Conclusion: The Er:YAG laser recycling of mini-screws is a proper method causing minimum damage to the screw surface.

5.
Dent Mater J ; 42(4): 610-616, 2023 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-37438118

RESUMO

Recently, the use of orthodontic mini-screws as an anchorage for orthodontic treatment is increasing, and the degree of osseointegration of the mini-screws affects the performance of orthodontic treatment. This study aimed to evaluate the biocompatibility and osseointegration of Titanium 6Aluminum 4Vanadium (Ti-6Al-4V) alloy orthodontic mini-screws with an ibandronate-loaded TiO2 nanotube (TNT) layer. The TNT layer was formed on the surface of the Ti-6Al-4V alloy orthodontic mini-screws and loaded with ibandronate. The TNT formed by anodic oxidation formed a completely self-organized and compact structure and was stably released for 7 days after loading with ibandronate. Mini-screws loaded with ibandronate were implanted into both tibias of rats, confirming rapid initial bone regeneration. We demonstrate that the release of stable ibandronate from the TNT layer of Ti-6Al-4V alloy orthodontic mini-screws can effectively improve biocompatibility and osseointegration.


Assuntos
Implantes Dentários , Nanotubos , Ratos , Animais , Titânio/química , Osseointegração , Ácido Ibandrônico , Ligas , Parafusos Ósseos , Propriedades de Superfície
6.
J World Fed Orthod ; 12(5): 229-236, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37423833

RESUMO

BACKGROUND: The aim of this study was to investigate the effects of orthodontic miniscrew pitch and thread shape on microdamage in cortical bone. The relationship between the microdamage and primary stability was also examined. METHODS: Ti6Al4V orthodontic miniscrews and 1.0-mm-thick cortical bone pieces from fresh porcine tibia were prepared. The orthodontic miniscrews had custom-made thread height (H) and pitch (P) size geometries, and were classified into three groups: control geometry; HCPC (HC; thread height = 0.12 mm, PC; pitch size = 0.60 mm), geometry with a narrower pitch; HCPN (HC; thread height = 0.12 mm, PN; pitch size = 0.30 mm), and geometry with a taller thread height; HTPC (HT; thread height = 0.36 mm, PC; pitch size = 0.60 mm). The orthodontic miniscrews were inserted into a pilot hole in the cortical bone, and maximum insertion torque and Periotest value were measured. After insertion, the samples were stained with basic fuchsin. Histological thin sections were obtained and the bone microdamage parameters, i.e., total crack length and total damage area, and insertion state parameters, i.e., orthodontic miniscrew surface length and bone compression area were calculated. RESULTS: The orthodontic miniscrews with the taller thread height resulted in lower primary stability with minimal bone compression and microdamage; however, the narrower thread pitch led to maximum bone compression and extensive bone microdamage. CONCLUSIONS: A wider thread pitch reduced microdamage, and decreased thread height resulted in increased bone compression, ultimately resulting in increased primary stability.


Assuntos
Parafusos Ósseos , Procedimentos de Ancoragem Ortodôntica , Animais , Suínos , Parafusos Ósseos/efeitos adversos , Procedimentos de Ancoragem Ortodôntica/efeitos adversos , Procedimentos de Ancoragem Ortodôntica/métodos , Osso e Ossos , Osso Cortical , Torque
7.
Photodiagnosis Photodyn Ther ; 41: 103288, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36640857

RESUMO

BACKGROUND: The present study evaluated the anti-biofilm and bystander effects of antimicrobial photo-sonodynamic therapy (aPSDT) on the polymicrobial periopathogenic biofilms formed on mini-screws coated with zinc oxide nanoparticles (ZnONPs). MATERIALS AND METHODS: Thirty orthodontic identical mini-screws were divided into 6 groups (n = 5) as follows: 1. negative control: uncoated mini-screw + phosphate-buffered saline (PBS), 2. positive control: uncoated mini-screw + 0.2% CHX, 3. coating control: coated mini-screw + PBS, 4. antimicrobial photodynamic therapy (aPDT): coated mini-screw+light emitting diode (LED), 5. Antimicrobial sonodynamic therapy (aSDT): coated mini-screw+ultrasound waves, and 6. aPSDT: coated mini-screw+LED+ultrasound waves. Electrostatic spray-assisted vapor deposition was employed to coat ZnONPs on titanium mini-screws. The biofilm inhibition test was used to assess the anti-biofilm efficacy against polymicrobial periopathogenic biofilms including Porphyromonas gingivitis, Prevotella intermedia, and Aggregatibacter actinomycetemcomitans, and the results were shown as the percent reduction of Log10 colony-forming unit (CFU)/mL. Following each treatment, the gene expression levels of TNF-α, IL-1ß, and IL-6 were evaluated on human gingival fibroblast (HGF) cells via quantitative real-time polymerase chain reaction (qRT-PCR) to reveal the bystander effects of aPSDT on HGF cells. RESULTS: A significant reduction in log10 CFU/mL of periopathogens was observed in groups treated with aPDT, aSDT, aPSDT, and 0.2% CHX up to 6.81, 6.63, 5.02, and 4.83 log, respectively, when compared with control groups (P<0.05). 0.2% CHX and aPSDT groups demonstrated significantly higher capacity in eliminating the periopathogen biofilm compared with other groups (P<0.05). The qRT-PCR showed that the expression level of inflammatory cytokines was significantly down regulated in aPDT, aSDT, and aPSDT groups (P<0.05). CONCLUSION: It was found that the ZnONPs-mediated aPSDT could significantly reduce periopathogen biofilm as well as the expression level of inflammatory cytokines.


Assuntos
Anti-Infecciosos , Nanopartículas , Fotoquimioterapia , Óxido de Zinco , Humanos , Fotoquimioterapia/métodos , Óxido de Zinco/farmacologia , Fármacos Fotossensibilizantes/farmacologia , Efeito Espectador , Anti-Infecciosos/farmacologia , Citocinas , Biofilmes
8.
Orthod Craniofac Res ; 26(2): 163-170, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-35751508

RESUMO

OBJECTIVE: This randomized controlled trial (RCT) aims to investigate the short-term effects of chlorhexidine mouthwash (MW) on gingival health surrounding orthodontic miniscrew implants (OMIs) and their overall survivability. MATERIALS AND METHODS: Thirty-two participants (mean age, 22.8 years) undergoing fixed orthodontic appliance treatment after maxillary premolar extraction were randomly allocated in a parallel fashion to either receive (1) MW with an active component of chlorhexidine or (2) a placebo. Each participant received two maxillary buccal OMIs for anchorage reinforcement purposes. Participants were assessed for their gingival oral health status around all inserted OMIs and had their OMI survivability recorded at three time points; T1 = 1 month, T2 = 3 months, and T3 = 6 months after OMI placement. A Kaplan-Meier plot was used to estimate the survival function of OMIs. RESULTS: All randomized participants completed the follow-up period. In terms of gingival oral health, there were no statistically significant differences at any time point between the chlorhexidine MW group and the placebo-controlled group (P > .05). One OMI was lost in the chlorhexidine MW group and another two OMIs in the control group. There was no significant difference between both groups in terms of survivability (P = .585). CONCLUSION: The use of chlorhexidine MW does not seem to have a significant clinical impact on gingival health around OMIs or their survivability in this pilot study.


Assuntos
Clorexidina , Antissépticos Bucais , Humanos , Adulto Jovem , Adulto , Clorexidina/uso terapêutico , Antissépticos Bucais/uso terapêutico , Aparelhos Ortodônticos Fixos , Índice de Placa Dentária , Índice Periodontal
9.
Korean J Orthod ; 52(6): 412-419, 2022 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-36424809

RESUMO

Objective: This study evaluated the effect of cyclic pre-calcification treatment on the improvement of bioactivity and osseointegration of Ti-6Al-4V mini-screws. Methods: The experimental groups were: an untreated group (UT), an anodized and heat-treated group (AH), and an anodized treatment followed by cyclic pre-calcification treatment group (ASPH). A bioactive material with calcium phosphate was coated on the mini-screws, and its effects on bioactivity and osseointegration were evaluated in in vitro and in vivo tests of following implantation in the rat tibia. Results: As a result of immersing the ASPH group in simulated body fluid for 2 days, protrusions appearing in the initial stage of hydroxyapatite precipitation were observed. On the 3rd day, the protrusions became denser, other protrusions overlapped and grew on it, and the calcium and phosphorus concentrations increased. The removal torque values increased significantly in the following order: UT group (2.08 ± 0.67 N·cm), AH group (4.10 ± 0.72 N·cm), and ASPH group (6.58 ± 0.66 N·cm) with the ASPH group showing the highest value (p < 0.05). In the ASPH group, new bone was observed that was connected to the threads, and it was confirmed that a bony bridge connected to the adjacent bone was formed. Conclusions: In conclusion, it was found that the surface treatment method used in the ASPH group improved the bioactivity and osseointegration of Ti-6Al-4V orthodontic mini-screws.

10.
Healthcare (Basel) ; 10(9)2022 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-36141358

RESUMO

This case report describes the orthodontic treatment of a 9-year-old girl who presented with multiple agenesis, maxillary contraction, and skeletal Class III malocclusion after the surgical removal of a melanocytic neuroectodermal tumour of infancy (MNTI) or the so-called melanocytic progonoma at 40 days of age. The lack of dental anchorage in the posterior segment of the second quadrant and the search for maximum control during suture expansion to reduce dental effects led to the use of a hybrid rapid palatal expander (RPE) with dental anchorage in the first quadrant and skeletal anchorage on the two miniscrews placed in the second quadrant, to allow a more even distribution of expansion forces. The expansion procedures performed with the hybrid anchorage device and extraoral traction demonstrate the possibility of solving the contraction in the posterior segments and anterior crossbite in a few months with maximum control of the applied forces, despite the objective difficulties related to the specificity of the case.

11.
Prog Orthod ; 23(1): 18, 2022 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-35661931

RESUMO

BACKGROUND: The use of palatal miniscrew offers the possibility to improve the effectiveness of orthodontic expansion devices. Palatal expanders supported by miniscrew can be applied with different clinical protocols. Some authors proposed the use of four palatal miniscrews during miniscrew-supported palatal expansion to maximize skeletal effects in young adults' treatment. However, bone availability decreases in the posterior paramedian palatal regions, making the positioning of the two-posterior paramedian palatal miniscrews challenging, when it is performed avoiding nasal cavities invasion. Some authors proposed miniscrews insertion in a specific region located laterally to the palatal process of the maxillary bone, and apically relatively to the dento-alveolar process. The aim of this study was to evaluate the bone thickness, cortical bone thickness, and mucosae depth of this anatomical site that, in this study, was defined as palatal posterior supra-alveolar insertion site. RESULTS: The evaluation of bone availability of palatal posterior supra-alveolar insertion site at different antero-posterior levels showed that the maximum amount of total bone thickness was found between the second premolar and the first molar. At this level total bone, thickness is significantly (p < .05) greater compared to the other sagittal sites and it offers on average around 2 mm of extra bone depth for miniscrew placement. Cortical bone thickness is adequate for primary miniscrew stability. Overall, cortical bone thickness considered at different insertion sites showed significant statistically (p < .05) differences. The findings of this study showed that palatal mucosa is particularly thick with average values ranging from 4 to 7 mm, and its extension ultimately affects miniscrew length selection. Palatal mucosa thickness showed no clinically significant differences comparing different sagittal and vertical insertion sites. Data also showed that palatal mucosal thickness slightly significantly increases (p < .05) with the inclination of the insertion axis relative to the occlusal plane. Finally, study findings showed that vertical growth pattern can significantly affect considered outcomes (p < .05). CONCLUSIONS: Palatal posterior supra-alveolar insertion site is an appropriate site for posterior insertion of palatal miniscrews. Considering high anatomical variation preliminary CBCT evaluation is important to achieve optimal miniscrew placement.


Assuntos
Procedimentos de Ancoragem Ortodôntica , Parafusos Ósseos , Tomografia Computadorizada de Feixe Cônico/métodos , Osso Cortical/diagnóstico por imagem , Humanos , Maxila/cirurgia , Mucosa , Técnica de Expansão Palatina , Adulto Jovem
12.
Prog Orthod ; 23(1): 11, 2022 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-35368222

RESUMO

BACKGROUND: Mini-screws are widely used as temporary anchorages in orthodontic treatment, but have the disadvantage of showing a high failure rate of about 10%. Therefore, orthodontic mini-screws should have high biocompatibility and retention. Previous studies have demonstrated that the retention of mini-screws can be improved by imparting bioactivity to the surface. The method for imparting bioactivity proposed in this paper is to sequentially perform anodization, periodic pre-calcification, and heat treatments with a Ti-6Al-4V ELI alloy mini-screw. MATERIALS AND METHODS: A TiO2 nanotube-structured layer was formed on the surface of the Ti-6Al-4V ELI alloy mini-screw through anodization in which a voltage of 20 V was applied to a glycerol solution containing 20 wt% H2O and 1.4 wt% NH4F for 60 min. Fine granular calcium phosphate precipitates of HA and octacalcium phosphate were generated as clusters on the surface through the cyclic pre-calcification and heat treatments. The cyclic pre-calcification treatment is a process of immersion in a 0.05 M NaH2PO4 solution and a saturated Ca(OH)2 solution at 90 °C for 1 min each. RESULTS: It was confirmed that the densely structured protrusions were precipitated, and Ca and P concentrations, which bind and concentrate endogenous bone morphogenetic proteins, increased on the surface after simulated body fluid (SBF) immersion test. In addition, the removal torque of the mini-screw fixed into rabbit tibias for 4 weeks was measured to be 8.70 ± 2.60 N cm. CONCLUSIONS: A noteworthy point in this paper is that the Ca and P concentrations, which provide a scaffold suitable for endogenous bone formation, further increased over time after SBF immersion of the APH group specimens. The other point is that our mini-screws have a significantly higher removal torque compared to untreated mini-screws. These results represent that the mini-screw proposed in this paper can be used as a mini-screw for orthodontics.


Assuntos
Temperatura Alta , Osseointegração , Ligas , Animais , Materiais Biocompatíveis , Parafusos Ósseos , Humanos , Coelhos , Titânio
13.
J Int Soc Prev Community Dent ; 11(5): 561-565, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34760801

RESUMO

OBJECTIVE: Chitosan is a biomaterial with antibacterial properties that may benefit from maintaining peri-miniscrew hygiene and preventing inflammation. This study aimed to evaluate the expression of inflammatory-related molecules from the gingival crevicular fluid (GCF) after treatment of 1% chitosan when compared with 0.2% chlorhexidine mouthwash of patients with orthodontic miniscrew. MATERIALS AND METHODS: A total of 30 subjects were divided into three groups: the first group received mouthwash containing 1% chitosan, the second group 0.2% chlorhexidine digluconate, and the control group received aquadest. The GCF was collected before and after 4 days of rinsing, and relative expressions of IL-1α and IL-1ß, cyclooxygenase-2 (COX-2), and inducible nitric oxide synthase (iNOS) were evaluated by real-time qPCR. RESULTS: The expression of IL-1α was the highest in chitosan-treated patients when compared with that of IL-1ß in between-groups. Patients receiving chlorhexidine have the highest expression of COX-2 and iNOS when compared with the chitosan and control groups, respectively. CONCLUSION: A mouthwash containing 1% of chitosan could suppress the expression of inflammatory mediators IL-1ß, COX-2, and iNOS.

14.
Materials (Basel) ; 14(21)2021 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-34771795

RESUMO

The orthodontic miniscrew (TADs) is a device that is fixed into bone in the short term for the purpose of enhancing orthodontic anchorage. The aim of our study was to investigate the structural and surface properties of recovered TADs after orthodontic treatment, and compare them to new TADs. TADs (n = 15) from the same manufacturer (Absoanchor; Dentos, Daegu, Korea) were assessed; n = 10 were recovered from patients after orthodontic treatment and n = 5 were new. We performed electrochemical investigations, scanning electron microscopy (SEM) and microbiological analysis. Qualitative analysis on general electrochemical polarization revealed that the TADs retrieved from the patients provided much lower current densities in the passivity zone, and the oxidative processes taking place on their surface were of lower intensity. The surface morphologies of the tips of the retrieved mini-implants showed less sharp tips and smooth surfaces. Defects in the form of pores or cracks could be identified in both evaluated TAD groups. All retrieved TADs showed signs of biological materials (SEM analysis) and contamination on their surfaces. In conclusion, these results can assist orthodontists in comprehending the complexities of TAD behavior with respect to their design and structure.

15.
Dent Mater J ; 40(5): 1270-1276, 2021 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-34193725

RESUMO

We aimed to elucidate stress distribution in miniscrews and the surrounding bone when miniscrews inserted at different depths were implanted vertically or obliquely. The distributions of the equivalent stress on the screw surface and the minimum principal stress in the surrounding bone were calculated using finite element models. When the miniscrews were inserted vertically and obliquely, screw head displacement, greatest equivalent stress on the miniscrew surface, and absolute value of minimum principal stresses in the surrounding bone decreased with increasing insertion depth. Stresses in the obliquely inserted miniscrew with upward traction were smaller than in other insertion conditions, irrespective of insertion depth. With the application of orthodontic force, stress distribution around the miniscrew and surrounding bone is closely related to the insertion depth and insertion angle, which mutually affect each other. In particular, the obliquely inserted miniscrew with upward traction might be the most secure against screw failure and fracture.


Assuntos
Procedimentos de Ancoragem Ortodôntica , Parafusos Ósseos , Análise do Estresse Dentário , Análise de Elementos Finitos , Estresse Mecânico
16.
Stomatologiia (Mosk) ; 100(3): 7-12, 2021.
Artigo em Russo | MEDLINE | ID: mdl-34180618

RESUMO

BACKGROUND: The aim of this research is the experimental study measuring stability of the orthodontic miniscrews «Turbo¼ designed in Russia in comparison with its foreign analogues, namely, «Vector Tas¼ (USA) and «BioRay¼ (Taiwan). MATERIAL AND METHODS: Four self-drilling orthodontic miniscrews of each manufacturer, i.e. «Vector Tas¼, USA, (10-mm length, 2-mm diameter), «BioRay¼, Taiwan, (10-mm length, 2-mm diameter), «Turbo¼, Russia, (9-mm length, 2-mm diameter), a total of 12 items, were inserted into native pig mandible sample. Their stability was estimated by torques using a dynamometer (Zahoransky AG, Germany) and «Periotest¼ device («Periotest M¼, Germany). This experiment was conducted in native pig mandible sample immediately after the screws' placement and in 7 days after loading at an angle 70°. RESULTS: After application of a load, the decreased torque values and increased Periotest values were registered in all orthodontic miniscrews. CONCLUSION: Orthodontic miniscrews «Turbo¼ designed in Russia are slightly inferior to «VectorTas¼ miniscrews and superior to «BioRay¼ miniscrews in primary stability and stability after 7 days under loading.


Assuntos
Procedimentos de Ancoragem Ortodôntica , Animais , Parafusos Ósseos , Desenho de Aparelho Ortodôntico , Federação Russa , Suínos , Torque
17.
Korean J Orthod ; 51(3): 157-165, 2021 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-33984223

RESUMO

OBJECTIVE: This study aimed to identify the clinical effectiveness of two different penetration depths of micro-osteoperforations (MOPs) on the rate of orthodontic tooth movement. METHODS: Twenty-four patients requiring the removal of the upper first premolar teeth were selected and randomly divided into two groups. The control group participants did not undergo MOPs. Participants in the experimental group underwent three MOPs each at 4-mm (MOP-4) and 7-mm (MOP-7) depths, which were randomly and equally performed to either the left or right side distal to the canine. The retraction amount was measured on three-dimensional digital models on the 28th day of retraction. MOP-related pain was measured using a visual analog scale (VAS). Between-group statistical differences in the VAS scores were determined using an independent t-test and those in canine retraction were determined using analysis of variance and posthoc Tukey test. RESULTS: No significant difference was found between the MOP- 4 (1.22 ± 0.29 mm/month) and MOP-7 (1.29 ± 0.31 mm/month) groups in terms of the canine retraction rate. Moreover, both the groups demonstrated a significantly higher canine movement than the control group (0.88 ± 0.19 mm/ month). MOPs did not significantly affect the mesialization of the posterior teeth (p > 0.05). Moreover, the pain scores in the MOP-4 and MOP-7 groups were similar and showed no statistically significant difference. CONCLUSIONS: Three MOPs with a depth of 4 mm can be performed as an effective method to increase the rate of tooth movement. However, three MOPs with depths of 4-7 mm does not additionally enhance tooth movement.

18.
Biology (Basel) ; 10(3)2021 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-33802266

RESUMO

The use of maxillary expanders has the effect of distancing the maxillary bones at the level of the median palatal suture. During maxillary expansion, the main resistance forces occur at the zygomatico-maxillary sutures, and not in the median palatal suture, which is the basic principle on which this method is based. In this observational study, we evaluated possible complications at the skeletal and dentoalveolar level after palatal split using miniscrew-assisted rapid palatal expansion (MARPE) associated or not with corticopuncture (CP) therapy. The study included 27 patients with maxillary transverse deficiency and unilateral or bilateral cross-bite. Skeletal and dentoalveolar changes were evaluated using cone beam computed tomography (CBCT) images acquired before and after expansion. The mid-palatal suture was separated in 88.88% of cases, buccal bone height of the alveolar crest had decreased at first molar both at oral and palatal level by approximately 2.07 mm in 40.7% of cases whilst the remaining 59.3% showed insignificant bone loss, with canines exhibiting buccal tipping of 4.10° in 62.5% of cases. Changes of the occlusal planes were observed in 10 cases (37%). Maxillary canines tended to show symmetric buccal inclinations relative to the maxillary basal bone. Six patients; 22.22% showed hypertrophy/hyperplasia of the palatal mucosa associated with ulcerations, erythema, itching, and discomfort in the area. Swelling at the mid-palatal suture after split was observed in all cases and was caused by the resultant force. No cases of necrosis of the palatal mucosa were observed. Although occlusal modifications occur after palatal split, especially in unilateral cross-bite cases, these changes can be treated with the help of fixed orthodontic appliances.

19.
Materials (Basel) ; 14(8)2021 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-33917087

RESUMO

Orthodontic miniscrews have gained popularity; however, they have some drawbacks, including screw loosening that results from bone resorption caused by excess microdamage created during screw insertion. Pilot hole preparation through the cortical bone is considered beneficial to avoid such microdamage, while an overly large pilot hole impairs primary stability. Hence, we used a human bone analogue to evaluate the microdamage and primary stability to estimate the optimal pilot hole size that would minimize the screw loosening risk. Ti6Al4V orthodontic miniscrews and 1.0-mm-thick synthetic cortical bone pieces were prepared. Various compressive loads were applied in indentation tests to test pieces' surfaces, and the microdamaged areas were confirmed as stress-whitening zones. Screw insertion tests were performed in which a miniscrew was inserted into the test pieces' pilot hole with a diameter of 0.7-1.2 mm in 0.1-mm intervals, and the stress-whitening area was measured. The insertion and removal torque were also measured to evaluate primary stability. The stress-whitening areas of the 1.0-1.2 mm pilot hole diameter groups were significantly smaller than those of the other groups (p < 0.05), whereas the 0.9 and 1.0 mm pilot hole diameter groups showed higher primary stability than other groups. In conclusion, the bone analogue could be utilized to evaluate microdamage in cortical bones and the primary stability of miniscrews.

20.
Surg Radiol Anat ; 43(6): 1001-1008, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33386930

RESUMO

PURPOSE: The purpose of this study was to determine the palatal bone and soft tissue thicknesses using a miniscrew-supported maxillary skeletal expander (MSE) in Class III malocclusion. METHODS: The thicknesses of the palatal bone and soft tissue were measured in cone-beam computed tomography images obtained from 58 patients. All 20 points were crossing points between five levels, which were defined at 3 mm intervals relative to the line connecting the central fossae of the first molar (Level 0), and 2 mm and 4 mm lateral to the anteroposterior reference line (AP line). RESULTS: The palatal bone was significantly thicker in males than females in the anterior palate up to Level 0, while there was no significant sex-related difference in the posterior palate. There was a tendency for the thickness to decrease in the posterior direction, except in females at 2 mm lateral to the AP line. The palatal soft tissue was significantly thicker in males than females in all positions. At 2 mm lateral to the AP line, the palatal soft tissue thickness decreased in the posterior direction. A 4 mm lateral to the AP line, it initially decreased in the posterior direction, and then increasing again at Level - 6 (6 mm posterior of Level 0). As the lateral distance from the AP line increased, the palatal bone thickness decreased while the palatal soft tissue thickness increased. CONCLUSIONS: These findings provide quantitative data on the palatal bone and soft tissue thicknesses for the miniscrew-supported MSE in the posterior palate.


Assuntos
Má Oclusão Classe III de Angle/cirurgia , Maxila/anormalidades , Técnica de Expansão Palatina/instrumentação , Palato Duro/anatomia & histologia , Palato Mole/anatomia & histologia , Adolescente , Adulto , Parafusos Ósseos , Tomografia Computadorizada de Feixe Cônico , Feminino , Humanos , Imageamento Tridimensional , Masculino , Maxila/diagnóstico por imagem , Maxila/cirurgia , Palato Duro/diagnóstico por imagem , Palato Duro/cirurgia , Palato Mole/diagnóstico por imagem , Palato Mole/cirurgia , Estudos Retrospectivos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...